Top 10 game tài xỉu-tài xỉu online uy tín

Top 10 game tài xỉu-tài xỉu online uy tín

  • The Push-in connection terminal blocks are characterized by the system features of the CLIPLINE complete system and by easy and tool-free wiring of conductors with ferrules or solid conductors
  • The compact design and front connection enable wiring in a confined space
  • In addition to the testing facility in the double function shaft, all terminal blocks provide an additional test connection
{关键字} {关键字}

 

Top 10 game tài xỉu-tài xỉu online uy tín

Orderkey 3210237
Packing unit 1 pc
Minimum order quantity 50 pc
Catalog page Page 81 (C-1-2019)
GTIN 4046356334549
Weight per Piece (excluding packing) 7.340 g
Custom tariff number 85369010
Country of origin PL (Poland)

Top 10 game tài xỉu-tài xỉu online uy tín

 

Top 10 game tài xỉu-tài xỉu online uy tín



{关键字} 

Circuit diagram

Back to top

 

Top 10 game tài xỉu-tài xỉu online uy tín

Note The max. current is determined by the diode. Installed: Diode 1N 4007, reverse voltage: 1300 V, maximum continuous current: 0.5 A.
Number of levels 1
Number of connections 2
Potentials 1
Nominal cross section 2.5 mm²
Color gray
Insulating material PA
Flammability rating according to UL 94 V0
Mounting type NS 35/7,5
Rated surge voltage 8 kV
Degree of pollution 3
Overvoltage category III
Insulating material group I
Maximum load current 0.5 A (with 4 mm² conductor cross section, rigid)
Nominal current IN 0.5 A
Nominal voltage UN 800 V
Open side panel Yes
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
Static insulating material application in cold -60 °C
Surface flammability NFPA 130 (ASTM E 162) passed
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 – HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 – HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 – HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 – HL 3

Back to top

 

Top 10 game tài xỉu-tài xỉu online uy tín

Width 5.2 mm
End cover width 2.2 mm
Length 48.5 mm
Height NS 35/7,5 36.5 mm
Height NS 35/15 44 mm

Back to top

 

Top 10 game tài xỉu-tài xỉu online uy tín

Connection 1 level
Connection method Push-in connection
Stripping length 8 mm … 10 mm
Conductor cross section solid min. 0.14 mm²
Conductor cross section solid max. 4 mm²
Conductor cross section AWG min. 26
Conductor cross section AWG max. 12
Conductor cross section flexible min. 0.14 mm²
Conductor cross section flexible max. 4 mm²
Min. AWG conductor cross section, flexible 26
Max. AWG conductor cross section, flexible 14
Conductor cross section flexible, with ferrule without plastic sleeve min. 0.14 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max. 2.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. 0.14 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max. 2.5 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 0.5 mm²
Connection cross sections directly pluggable 0.34 mm² 4 mm²
Conductor cross section solid min. 0.34 mm²
Conductor cross section solid max. 4 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min. 0.34 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max. 2.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. 0.34 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max. 2.5 mm²
Internal cylindrical gage A3

Back to top

 

Top 10 game tài xỉu-tài xỉu online uy tín

Operating temperature -60 °C … 105 °C (max. short-term operating temperature 130°C)
Ambient temperature (storage/transport) -25 °C … 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport) 30 % … 70 %
Ambient temperature (assembly) -5 °C … 70 °C
Ambient temperature (actuation) -5 °C … 70 °C

Back to top

 

Top 10 game tài xỉu-tài xỉu online uy tín

Connection in acc. with standard CSA
Flammability rating according to UL 94 V0

Back to top

 

Top 10 game tài xỉu-tài xỉu online uy tín

REACh SVHC Lead 2022-10-12
China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration”

Top 10 game tài xỉu-tài xỉu online uy tínBack to top

Top 10 game tài xỉu-tài xỉu online uy tín

 

Top 10 game tài xỉu-tài xỉu online uy tín

ECLASS 10.0.1 27141127
ECLASS 11.0 27141127
ECLASS 4.0 27141100
ECLASS 4.1 27141100
ECLASS 5.0 27141100
ECLASS 5.1 27141100
ECLASS 6.0 27141100
ECLASS 7.0 27141127
ECLASS 9.0 27141127

Back to top

 

Top 10 game tài xỉu-tài xỉu online uy tín

ETIM 2.0 EC000897
ETIM 3.0 EC000897
ETIM 4.0 EC000897
ETIM 6.0 EC000903
ETIM 7.0 EC000903

Back to top

 

Top 10 game tài xỉu-tài xỉu online uy tín

UNSPSC 6.01 30211811
UNSPSC 7.0901 39121410
UNSPSC 11 39121410
UNSPSC 12.01 39121410
UNSPSC 13.2 39121410
UNSPSC 18.0 39121410
UNSPSC 19.0 39121410
UNSPSC 20.0 39121410
UNSPSC 21.0 39121410